{"id":"CVE-2024-34033","published":"2024-05-03T00:20:03Z","modified":"2024-08-12T20:08:16Z","title":"Path Traversal vulnerability in Delta Electronics DIAEnergie","vendor":"Delta Electronics","product":"DIAEnergie ","tier":"tail","description":{"text":"\nDelta Electronics DIAEnergie has insufficient input validation which makes it possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.\n\n","provenance":"source","from":"CVE.org"},"cvss":{"score":8.8,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.01,"percentile":0.63633,"provenance":"source"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-02","tags":["government-resource"]}],"priority":{"score":18.9,"factors":[{"name":"EPSS percentile","points":12.73},{"name":"CVSS severity","points":6.16}]},"vendorSlug":"delta-electronics","affectedVersions":[{"vendor":"Delta Electronics","product":"DIAEnergie ","versions":["1.10.00.005"]}],"solutions":{"items":["Delta Electronics recommends users update to DIAEnergie v1.10.01.004 to mitigate these vulnerabilities. Users can request this version of DIAEnergie from Delta Electronics' regional sales or agents."],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2024-06-26T17:53:32.429375Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2024-34602","exploited":false,"provenance":"source"}}