{"id":"CVE-2024-3742","published":"2024-04-18T22:15:35Z","modified":"2024-08-01T20:20:00Z","title":"Electrolink FM/DAB/TV Transmitter Cleartext Storage of Sensitive Information","vendor":"Electrolink","product":"Compact DAB Transmitter","tier":"tail","description":{"text":"Electrolink transmitters store credentials in clear-text. Use of these credentials could allow an attacker to access the system.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.5,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.01418,"percentile":0.73449,"provenance":"source"},"cwes":[{"id":"CWE-312","name":"Cleartext Storage of Sensitive Information"}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-02","tags":[]}],"priority":{"score":24.9,"factors":[{"name":"EPSS percentile","points":14.69},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":5.25}]},"exploitSources":{"nuclei":[{"id":"CVE-2024-3742","name":"Electrolink FM/DAB/TV Transmitter (controlloLogin.js) - Credentials Disclosure","severity":"high","path":"http/cves/2024/CVE-2024-3742.yaml","url":"https://github.com/projectdiscovery/nuclei-templates/blob/main/http/cves/2024/CVE-2024-3742.yaml"}],"provenance":"source"},"vendorSlug":"electrolink","affectedVersions":[{"vendor":"Electrolink","product":"Compact DAB Transmitter","versions":["10W","100W","250W"]},{"vendor":"Electrolink","product":"Medium DAB Transmitter","versions":["500W","1kW","2kW"]},{"vendor":"Electrolink","product":"High Power DAB Transmitter","versions":["2.5kW","3kW","4kW","5kW"]},{"vendor":"Electrolink","product":"Compact FM Transmitter","versions":["Compact FM Transmitter","500W","1kW","2kW"]},{"vendor":"Electrolink","product":"Modular FM Transmitter","versions":["3kW","5kW","10kW","15kW","20kW","30kW"]},{"vendor":"Electrolink","product":"Digital FM Transmitter","versions":[">= 15W, <= 40kW"]},{"vendor":"Electrolink","product":"VHF TV Transmitter","versions":["BI","BIII"]},{"vendor":"Electrolink","product":"UHF TV Transmitter","versions":[">= 10W, <= 5kW"]}],"workarounds":{"items":["Electrolink has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of the affected products are encouraged to contact Electrolink https://electrolink.com/contacts/ for additional information."],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial","timestamp":"2024-05-07T15:38:32.607032Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2024-32316","exploited":false,"provenance":"source"}}