{"id":"CVE-2024-39568","published":"2024-07-09T12:05:12Z","modified":"2025-08-27T20:42:55Z","title":"A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1)","vendor":"Siemens","product":"SINEMA Remote Connect Client","tier":"tail","description":{"text":"A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1). The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading proxy configurations. This could allow an authenticated local attacker to execute arbitrary code with system privileges.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.8,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.0144,"percentile":0.73417,"provenance":"source"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-868282.html","tags":[]}],"priority":{"score":20.1,"factors":[{"name":"EPSS percentile","points":14.68},{"name":"CVSS severity","points":5.46}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SINEMA Remote Connect Client","versions":["< V3.2 HF1"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2024-07-23T13:43:31.750107Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2024-38092","exploited":false,"provenance":"source"}}