{"id":"CVE-2024-39569","published":"2024-07-09T12:05:14Z","modified":"2025-08-27T20:42:55Z","title":"A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1)","vendor":"Siemens","product":"SINEMA Remote Connect Client","tier":"tail","description":{"text":"A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1). The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading VPN configurations. This could allow an administrative remote attacker running a corresponding SINEMA Remote Connect Server to execute arbitrary code with system privileges on the client system.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.6,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.01622,"percentile":0.76461,"provenance":"source"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-868282.html","tags":[]}],"priority":{"score":19.9,"factors":[{"name":"EPSS percentile","points":15.29},{"name":"CVSS severity","points":4.62}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SINEMA Remote Connect Client","versions":["< V3.2 HF1"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2025-01-14T14:30:31.535023Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2024-38093","exploited":false,"provenance":"source"}}