{"id":"CVE-2024-39876","published":"2024-07-09T12:05:34Z","modified":"2025-08-27T20:42:57Z","title":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1)","vendor":"Siemens","product":"SINEMA Remote Connect Server","tier":"tail","description":{"text":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected applications do not properly handle log rotation. This could allow an unauthenticated remote attacker to cause a denial of service condition through resource exhaustion on the device.","provenance":"source","from":"CVE.org"},"cvss":{"score":4,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00206,"percentile":0.10843,"provenance":"source"},"cwes":[{"id":"CWE-770","name":"Allocation of Resources Without Limits or Throttling"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-381581.html","tags":[]}],"priority":{"score":5.0,"factors":[{"name":"EPSS percentile","points":2.17},{"name":"CVSS severity","points":2.8}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SINEMA Remote Connect Server","versions":["< V3.2 SP1"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2024-07-18T19:50:03.545280Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2024-38281","exploited":false,"provenance":"source"}}