{"id":"CVE-2024-4080","published":"2024-07-23T13:29:55Z","modified":"2026-11-11T20:51:48Z","title":"Memory Corruption Due to Improper Length Checks in LabVIEW tdcore.dll","vendor":"NI","product":"LabVIEW","tier":"tail","description":{"text":"A memory corruption issue due to an improper length check in LabVIEW tdcore.dll may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.8,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00271,"percentile":0.19719,"provenance":"source"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"}],"references":[{"url":"https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-issues-due-to-improper-length-checks-in-labview.html","tags":[]}],"priority":{"score":9.4,"factors":[{"name":"EPSS percentile","points":3.94},{"name":"CVSS severity","points":5.46}]},"vendorSlug":"ni","affectedVersions":[{"vendor":"NI","product":"LabVIEW","versions":["< 24.3.0"]}],"capec":[{"id":"CAPEC-14","name":"Client-side Injection-induced Buffer Overflow"}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2024-07-24T15:08:22.993606Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2024-32642","exploited":false,"provenance":"source"}}