{"id":"CVE-2024-43649","published":"2025-01-09T07:56:46Z","modified":"2025-03-11T13:07:05Z","title":"Authenticated command injection via <redacted>.exe <redacted> parameter","vendor":"Iocharger","product":"Iocharger firmware for AC models","tier":"tail","description":{"text":"Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user.\n\nThis issue affects Iocharger firmware for AC models before version 24120701.\n\nLikelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.\n\nImpact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.\n\nCVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to \"pivot\" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).","provenance":"source","from":"CVE.org"},"cvss":{"score":9.3,"severity":"CRITICAL","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.03694,"percentile":0.90481,"provenance":"source"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-250","name":"Execution with Unnecessary Privileges"}],"references":[{"url":"https://csirt.divd.nl/DIVD-2024-00035/","tags":["third-party-advisory"]},{"url":"https://csirt.divd.nl/CVE-2024-43649/","tags":["third-party-advisory"]},{"url":"https://iocharger.com","tags":["product"]}],"priority":{"score":24.6,"factors":[{"name":"EPSS percentile","points":18.1},{"name":"CVSS severity","points":6.51}]},"vendorSlug":"iocharger","affectedVersions":[{"vendor":"Iocharger","product":"Iocharger firmware for AC models","versions":["< 24120701"]}],"capec":[{"id":"CAPEC-88","name":"OS Command Injection"}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2025-01-09T14:35:10.473442Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2024-40393","exploited":false,"provenance":"source"}}