{"id":"CVE-2024-43656","published":"2025-01-09T07:56:45Z","modified":"2025-03-11T13:07:22Z","title":"A backup can be manipulated and then restored to create arbitrary files inside the <redacted> directory. A CGI script…","vendor":"Iocharger","product":"Iocharger firmware for AC models","tier":"tail","description":{"text":"Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root\n\nThis issue affects Iocharger firmware for AC model chargers before version 24120701.\n\nLikelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.\n\nImpact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).","provenance":"source","from":"CVE.org"},"cvss":{"score":9.3,"severity":"CRITICAL","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.01525,"percentile":0.75288,"provenance":"source"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-434","name":"Unrestricted Upload of File with Dangerous Type"}],"references":[{"url":"https://csirt.divd.nl/DIVD-2024-00035/","tags":["third-party-advisory"]},{"url":"https://csirt.divd.nl/CVE-2024-43656/","tags":["third-party-advisory"]},{"url":"https://iocharger.com","tags":["product"]}],"priority":{"score":21.6,"factors":[{"name":"EPSS percentile","points":15.06},{"name":"CVSS severity","points":6.51}]},"vendorSlug":"iocharger","affectedVersions":[{"vendor":"Iocharger","product":"Iocharger firmware for AC models","versions":["< 24120701"]}],"capec":[{"id":"CAPEC-88","name":"OS Command Injection"}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2025-01-09T14:49:55.938365Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2024-40400","exploited":false,"provenance":"source"}}