{"id":"CVE-2024-46894","published":"2024-11-12T12:49:45Z","modified":"2024-11-12T14:19:46Z","title":"A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3)","vendor":"Siemens","product":"SINEC INS","tier":"tail","description":{"text":"A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly validate authorization of a user to query the \"/api/sftp/users\" endpoint. This could allow an authenticated remote attacker to gain knowledge about the list of configured users of the SFTP service and also modify that configuration.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00497,"percentile":0.35466,"provenance":"source"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"},{"id":"CWE-276","name":"Incorrect Default Permissions"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-915275.html","tags":[]}],"priority":{"score":11.5,"factors":[{"name":"EPSS percentile","points":7.09},{"name":"CVSS severity","points":4.41}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SINEC INS","versions":["< V1.0 SP2 Update 3"]}],"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial","timestamp":"2024-11-12T14:16:33.854628Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2024-42140","exploited":false,"provenance":"source"}}