{"id":"CVE-2024-47902","published":"2024-10-23T14:21:20Z","modified":"2024-10-23T18:16:39Z","title":"A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707…","vendor":"Siemens","product":"InterMesh 7177 Hybrid 2.0 Subscriber","tier":"tail","description":{"text":"A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not authenticate GET requests that execute specific commands (such as `ping`) on operating system level.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.2,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00507,"percentile":0.44198,"provenance":"source"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-333468.html","tags":[]}],"priority":{"score":13.9,"factors":[{"name":"EPSS percentile","points":8.84},{"name":"CVSS severity","points":5.04}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"InterMesh 7177 Hybrid 2.0 Subscriber","versions":["< V8.2.12"]},{"vendor":"Siemens","product":"InterMesh 7707 Fire Subscriber","versions":["< V7.2.12"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2024-10-23T18:15:15.404634Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2024-42717","exploited":false,"provenance":"source"}}