{"id":"CVE-2024-52504","published":"2025-08-12T11:16:48Z","modified":"2025-08-12T19:15:53Z","title":"A vulnerability has been identified in SIPROTEC 4 6MD61 (All versions), SIPROTEC 4 6MD63 (All versions), SIPROTEC 4…","vendor":"Siemens","product":"SIPROTEC 4 6MD61","tier":"tail","description":{"text":"A vulnerability has been identified in SIPROTEC 4 6MD61 (All versions), SIPROTEC 4 6MD63 (All versions), SIPROTEC 4 6MD66 (All versions), SIPROTEC 4 6MD665 (All versions), SIPROTEC 4 7SA522 (All versions), SIPROTEC 4 7SA6 (All versions < V4.78), SIPROTEC 4 7SD5 (All versions < V4.78), SIPROTEC 4 7SD610 (All versions < V4.78), SIPROTEC 4 7SJ61 (All versions), SIPROTEC 4 7SJ62 (All versions), SIPROTEC 4 7SJ63 (All versions), SIPROTEC 4 7SJ64 (All versions), SIPROTEC 4 7SJ66 (All versions), SIPROTEC 4 7SS52 (All versions), SIPROTEC 4 7ST6 (All versions), SIPROTEC 4 7UM61 (All versions), SIPROTEC 4 7UM62 (All versions), SIPROTEC 4 7UT612 (All versions), SIPROTEC 4 7UT613 (All versions), SIPROTEC 4 7UT63 (All versions), SIPROTEC 4 7VE6 (All versions), SIPROTEC 4 7VK61 (All versions), SIPROTEC 4 7VU683 (All versions), SIPROTEC 4 Compact 7RW80 (All versions), SIPROTEC 4 Compact 7SD80 (All versions), SIPROTEC 4 Compact 7SJ80 (All versions), SIPROTEC 4 Compact 7SJ81 (All versions), SIPROTEC 4 Compact 7SK80 (All versions), SIPROTEC 4 Compact 7SK81 (All versions). Affected devices do not properly handle interrupted operations of file transfer. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the devices need to be restarted.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.5,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00518,"percentile":0.44924,"provenance":"source"},"cwes":[{"id":"CWE-754","name":"Improper Check for Unusual or Exceptional Conditions"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-400089.html","tags":[]}],"priority":{"score":14.2,"factors":[{"name":"EPSS percentile","points":8.98},{"name":"CVSS severity","points":5.25}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SIPROTEC 4 6MD61","versions":["all versions"]},{"vendor":"Siemens","product":"SIPROTEC 4 6MD63","versions":["all versions"]},{"vendor":"Siemens","product":"SIPROTEC 4 6MD66","versions":["all versions"]},{"vendor":"Siemens","product":"SIPROTEC 4 6MD665","versions":["all versions"]},{"vendor":"Siemens","product":"SIPROTEC 4 7SA522","versions":["all versions"]},{"vendor":"Siemens","product":"SIPROTEC 4 7SA6","versions":["< V4.78"]},{"vendor":"Siemens","product":"SIPROTEC 4 7SD5","versions":["< V4.78"]},{"vendor":"Siemens","product":"SIPROTEC 4 7SD610","versions":["< V4.78"]},{"vendor":"Siemens","product":"SIPROTEC 4 7SJ61","versions":["all versions"]},{"vendor":"Siemens","product":"SIPROTEC 4 7SJ62","versions":["all versions"]}],"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial","timestamp":"2025-08-12T19:09:20.387727Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2024-54863","exploited":false,"provenance":"source"}}