{"id":"CVE-2024-53648","published":"2025-02-11T10:28:52Z","modified":"2025-11-11T20:20:22Z","title":"A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP200) (All…","vendor":"Siemens","product":"SIPROTEC 5 6MD84 (CP300)","tier":"tail","description":{"text":"A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.90), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions < V9.90), SIPROTEC 5 6MU85 (CP300) (All versions < V9.90), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V10.0), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.90), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.90), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.90), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.90), SIPROTEC 5 7SK82 (CP100) (All versions < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.90), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.90), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.90), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.90), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.90), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions < V9.90), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.90). Affected devices do not properly limit access to a development shell accessible over a physical interface. This could allow an unauthenticated attacker with physical access to the device to execute arbitrary commands on the device.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.8,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00323,"percentile":0.26,"provenance":"source"},"cwes":[{"id":"CWE-489","name":"Active Debug Code"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-687955.html","tags":[]}],"priority":{"score":10.0,"factors":[{"name":"EPSS percentile","points":5.2},{"name":"CVSS severity","points":4.76}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SIPROTEC 5 6MD84 (CP300)","versions":["< V9.90"]},{"vendor":"Siemens","product":"SIPROTEC 5 6MD85 (CP200)","versions":["all versions"]},{"vendor":"Siemens","product":"SIPROTEC 5 6MD85 (CP300)","versions":["< V9.90"]},{"vendor":"Siemens","product":"SIPROTEC 5 6MD86 (CP200)","versions":["all versions"]},{"vendor":"Siemens","product":"SIPROTEC 5 6MD86 (CP300)","versions":["< V9.90"]},{"vendor":"Siemens","product":"SIPROTEC 5 6MD89 (CP300)","versions":["< V9.90"]},{"vendor":"Siemens","product":"SIPROTEC 5 6MU85 (CP300)","versions":["< V9.90"]},{"vendor":"Siemens","product":"SIPROTEC 5 7KE85 (CP200)","versions":["all versions"]},{"vendor":"Siemens","product":"SIPROTEC 5 7KE85 (CP300)","versions":["< V10.0"]},{"vendor":"Siemens","product":"SIPROTEC 5 7SA82 (CP100)","versions":["< V8.90"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2025-02-11T14:35:44.427665Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2024-52017","exploited":false,"provenance":"source"}}