{"id":"CVE-2024-56837","published":"2025-12-09T10:44:15Z","modified":"2026-01-13T09:43:52Z","title":"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.0), RUGGEDCOM ROX MX5000RE (All…","vendor":"Siemens","product":"RUGGEDCOM ROX MX5000","tier":"tail","description":{"text":"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.0), RUGGEDCOM ROX MX5000RE (All versions < V2.17.0), RUGGEDCOM ROX RX1400 (All versions < V2.17.0), RUGGEDCOM ROX RX1500 (All versions < V2.17.0), RUGGEDCOM ROX RX1501 (All versions < V2.17.0), RUGGEDCOM ROX RX1510 (All versions < V2.17.0), RUGGEDCOM ROX RX1511 (All versions < V2.17.0), RUGGEDCOM ROX RX1512 (All versions < V2.17.0), RUGGEDCOM ROX RX1524 (All versions < V2.17.0), RUGGEDCOM ROX RX1536 (All versions < V2.17.0), RUGGEDCOM ROX RX5000 (All versions < V2.17.0). Due to the insufficient validation during the installation and load of certain configuration files of the affected device, an attacker could spawn a reverse shell and gain root access on the affected system.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.2,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00716,"percentile":0.4953,"provenance":"source"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-912274.html","tags":[]}],"priority":{"score":14.9,"factors":[{"name":"EPSS percentile","points":9.91},{"name":"CVSS severity","points":5.04}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"RUGGEDCOM ROX MX5000","versions":["< V2.17.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX MX5000RE","versions":["< V2.17.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1400","versions":["< V2.17.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1500","versions":["< V2.17.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1501","versions":["< V2.17.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1510","versions":["< V2.17.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1511","versions":["< V2.17.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1512","versions":["< V2.17.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1524","versions":["< V2.17.0"]},{"vendor":"Siemens","product":"RUGGEDCOM ROX RX1536","versions":["< V2.17.0"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2025-12-09T14:28:47.566460Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2024-55307","exploited":false,"provenance":"source"}}