{"id":"CVE-2024-7988","published":"2024-08-26T14:47:07Z","modified":"2024-08-26T17:46:47Z","title":"ThinManager® ThinServer™ Information Disclosure and Remote Code Execution Vulnerabilities","vendor":"Rockwell Automation","product":"ThinManager® ThinServer™","tier":"tail","description":{"text":"A remote code execution vulnerability exists in the Rockwell Automation ThinManager® ThinServer™ that allows a threat actor to execute arbitrary code with System privileges. This vulnerability exists due to the lack of proper data input validation, which allows files to be overwritten.","provenance":"source","from":"CVE.org"},"cvss":{"score":9.3,"severity":"CRITICAL","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.04784,"percentile":0.92138,"provenance":"source"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1692.html","tags":[]}],"priority":{"score":24.9,"factors":[{"name":"EPSS percentile","points":18.43},{"name":"CVSS severity","points":6.51}]},"vendorSlug":"rockwell-automation","affectedVersions":[{"vendor":"Rockwell Automation","product":"ThinManager® ThinServer™","versions":["11.1.0-11.1.7 11.2.0-11.2.8 12.0.0-12.0.6 12.1.0-12.1.7 13.0.0-13.0.4 13.1.0-13.1.2 13.2.0-13.2.1"]}],"solutions":{"items":["Affected Product First Known in software version Corrected in software version ThinManager® ThinServer™ 11.1.0-11.1.7 11.2.0-11.2.8 12.0.0-12.0.6 12.1.0-12.1.7 13.0.0-13.0.4 13.1.0-13.1.2 13.2.0-13.2.1 11.1.8 11.2.9 12.0.7 12.1.8 13.0.5 13.1.3 13.2.2 Mitigations and Workarounds Customers using the affected software are encouraged to implement our suggested security best practices to minimize the risk of vulnerability. ·       Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"],"from":"CVE.org CNA","provenance":"source"},"capec":[{"id":"CAPEC-153","name":"Input Data Manipulation"}],"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"total","timestamp":"2024-08-26T17:39:20.975738Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"The ThinManager ThinServer component of Rockwell Automation's ThinManager product contains a flaw caused by improper input validation that allows files to be overwritten. An attacker who can reach the ThinServer over the network can exploit this without authentication or user interaction to execute arbitrary code with System privileges.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-20T06:34:31Z"},"euvd":{"id":"EUVD-2024-48819","exploited":false,"provenance":"source"}}