{"id":"CVE-2025-10634","published":"2025-09-18T01:02:15Z","modified":"2025-09-18T13:18:03Z","title":"D-Link DIR-823X Environment Variable goahead sub_412E7C command injection","vendor":"D-Link","product":"DIR-823X","tier":"tail","description":{"text":"A weakness has been identified in D-Link DIR-823X 240126/240802/250416. The impacted element is the function sub_412E7C of the file /usr/sbin/goahead of the component Environment Variable Handler. This manipulation of the argument terminal_addr/server_ip/server_port causes command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be exploited.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.07451,"percentile":0.95203,"provenance":"source"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"},{"id":"CWE-74","name":"Improper Neutralization of Special Elements in Output Used by a Downstream Component"}],"references":[{"url":"https://vuldb.com/?id.324662","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.324662","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.650792","tags":["third-party-advisory"]},{"url":"https://github.com/Cpppq43/D-Link/blob/main/DIink-DIR-823x.md","tags":["related"]},{"url":"https://pan.baidu.com/s/1dWnXEa58P0KHw53L9U_PoQ","tags":["exploit"]},{"url":"https://www.dlink.com/","tags":["product"]}],"priority":{"score":28.5,"factors":[{"name":"EPSS percentile","points":19.04},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":4.41}]},"vendorSlug":"d-link","affectedVersions":[{"vendor":"D-Link","product":"DIR-823X","versions":["240126","240802","250416"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2025-09-18T13:18:00.456496Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"A command injection flaw exists in the Environment Variable Handler component of the D-Link DIR-823X router firmware, specifically in function sub_412E7C of the /usr/sbin/goahead binary, where the terminal_addr, server_ip and server_port arguments are not properly neutralised. An attacker with low-privilege authenticated access can exploit it remotely over the network, without requiring user interaction, to inject and execute operating system commands on the device.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:18:58Z"},"euvd":{"id":"EUVD-2025-29841","exploited":false,"provenance":"source"},"exploitRefs":["https://pan.baidu.com/s/1dWnXEa58P0KHw53L9U_PoQ"]}