{"id":"CVE-2025-11298","published":"2025-10-05T18:02:05Z","modified":"2026-02-24T06:42:41Z","title":"Belkin F9K1015 formSetWanStatic command injection","vendor":"Belkin","product":"F9K1015","tier":"tail","description":{"text":"A vulnerability was determined in Belkin F9K1015 1.00.10. Impacted is an unknown function of the file /goform/formSetWanStatic. Executing a manipulation of the argument m_wan_ipaddr can lead to command injection. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.05604,"percentile":0.93096,"provenance":"source"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"},{"id":"CWE-74","name":"Improper Neutralization of Special Elements in Output Used by a Downstream Component"}],"references":[{"url":"https://vuldb.com/?id.327179","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.327179","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.661302","tags":["third-party-advisory"]},{"url":"https://github.com/panda666-888/vuls/blob/main/belkin/f9k1015/formSetWanStatic.md","tags":["related"]},{"url":"https://github.com/panda666-888/vuls/blob/main/belkin/f9k1015/formSetWanStatic.md#poc","tags":["exploit"]}],"priority":{"score":28.0,"factors":[{"name":"EPSS percentile","points":18.62},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":4.41}]},"vendorSlug":"belkin","affectedVersions":[{"vendor":"Belkin","product":"F9K1015","versions":["1.00.10"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2025-10-06T17:18:34.856788Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"The Belkin F9K1015 (firmware 1.00.10) contains a command injection flaw in the formSetWanStatic handler at /goform/formSetWanStatic, where the m_wan_ipaddr argument is not properly neutralised before use. An attacker with remote network access and low privileges (no user interaction required) can manipulate that argument to inject and run operating system commands on the device.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:19:16Z"},"euvd":{"id":"EUVD-2025-32237","exploited":false,"provenance":"source"},"exploitRefs":["https://github.com/panda666-888/vuls/blob/main/belkin/f9k1015/formSetWanStatic.md#poc"]}