{"id":"CVE-2025-1235","published":"2025-06-02T06:23:19Z","modified":"2025-06-02T17:03:08Z","title":"WAGO: Switches affected by year 2k38 problem","vendor":"WAGO","product":"Fully Managed Switches 0852-0303","tier":"tail","description":{"text":"A low privileged attacker can set the date of the devices to the 19th of January 2038 an therefore exceed the 32-Bit time limit. This causes the date of the switch to be set back to January 1st, 1970.","provenance":"source","from":"CVE.org"},"cvss":{"score":4.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00293,"percentile":0.22392,"provenance":"source"},"cwes":[{"id":"CWE-190","name":"Integer Overflow or Wraparound"}],"references":[{"url":"https://cert.vde.com/en/advisories/VDE-2025-020","tags":[]}],"priority":{"score":7.5,"factors":[{"name":"EPSS percentile","points":4.48},{"name":"CVSS severity","points":3.01}]},"vendorSlug":"wago","affectedVersions":[{"vendor":"WAGO","product":"Fully Managed Switches 0852-0303","versions":["all"]},{"vendor":"WAGO","product":"Fully Managed Switches 0852-1305","versions":["all"]},{"vendor":"WAGO","product":"Fully Managed Switches 0852-1305/0000-0001","versions":["all"]},{"vendor":"WAGO","product":"Fully Managed Switches 0852-1505","versions":["all"]},{"vendor":"WAGO","product":"Fully Managed Switches 0852-1505/0000-0001","versions":["all"]},{"vendor":"WAGO","product":"Lean Managed Switches 0852-1812","versions":["all"]},{"vendor":"WAGO","product":"Lean Managed Switches 0852-1812/0010-0000","versions":["all"]},{"vendor":"WAGO","product":"Lean Managed Switches 0852-1813","versions":["all"]},{"vendor":"WAGO","product":"Lean Managed Switches 0852-1813/0000-0001","versions":["all"]},{"vendor":"WAGO","product":"Lean Managed Switches 0852-1813/0010-0000","versions":["all"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2025-06-02T17:02:26.990253Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2025-16610","exploited":false,"provenance":"source"}}