{"id":"CVE-2025-14093","published":"2025-12-05T16:32:05Z","modified":"2026-02-24T05:41:17Z","title":"Edimax BR-6478AC V3 formTracerouteDiagnosticRun sub_416990 os command injection","vendor":"Edimax","product":"BR-6478AC V3","tier":"tail","description":{"text":"A vulnerability was detected in Edimax BR-6478AC V3 1.0.15. Impacted is the function sub_416990 of the file /boafrm/formTracerouteDiagnosticRun. The manipulation of the argument host results in os command injection. The attack can be launched remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","provenance":"source","from":"CVE.org"},"cvss":{"score":4.7,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.13541,"percentile":0.97125,"provenance":"source"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"references":[{"url":"https://vuldb.com/?id.334483","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.334483","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.696633","tags":["third-party-advisory"]},{"url":"https://github.com/Kriswu1337/CVE/blob/main/EDIMAX/1/2.md","tags":["exploit"]}],"priority":{"score":27.7,"factors":[{"name":"EPSS percentile","points":19.42},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":3.29}]},"vendorSlug":"edimax","affectedVersions":[{"vendor":"Edimax","product":"BR-6478AC V3","versions":["1.0.15"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2025-12-05T19:54:21.946530Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"The Edimax BR-6478AC V3 router (firmware 1.0.15) contains an OS command injection flaw in the sub_416990 function of the /boafrm/formTracerouteDiagnosticRun handler, where the host argument is not properly neutralised before being passed to a system command. An attacker with remote network access and high privileges (authenticated access to the device) can inject arbitrary operating system commands through the host parameter, with low attack complexity and no user interaction required.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:19:37Z"},"euvd":{"id":"EUVD-2025-201448","exploited":false,"provenance":"source"},"exploitRefs":["https://github.com/Kriswu1337/CVE/blob/main/EDIMAX/1/2.md"]}