{"id":"CVE-2025-14097","published":"2025-12-17T12:36:03Z","modified":"2025-12-17T14:41:13Z","title":"Remote Code Execution Vulnerability in Radiometer Products","vendor":"Radiometer Medical Aps","product":"ABL90 FLEX and ABL90 FLEX PLUS Analyzers","tier":"tail","description":{"text":"A vulnerability in the application software of multiple Radiometer products may allow remote code execution and unauthorized device management when specific internal conditions are met. Exploitation requires that a remote connection is established with additional information obtained through other means.  The issue is caused by a weakness in the analyzer’s application software.                                                                                                                                                                                                Other related CVE's are CVE-2025-14095 & CVE-2025-14096.                                                                                                      Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.\n\n\n\nRequired Configuration for Exposure: Affected application software version is in use and remote support feature is enabled in the analyzer.                                                                                                                                                                        Temporary work Around: If the network is not considered secure, please remove the analyzer from the network.                         Permanent solution:\nCustomers should ensure the following:\n•  The network is secure, and access follows best practices.\nLocal Radiometer representatives will contact all affected customers to discuss a permanent solution.                                                     \nExploit Status:\n\n\nResearchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.2,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00934,"percentile":0.59052,"provenance":"source"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"references":[{"url":"https://www.radiometer.com/myradiometer","tags":[]}],"priority":{"score":16.9,"factors":[{"name":"EPSS percentile","points":11.81},{"name":"CVSS severity","points":5.04}]},"vendorSlug":"radiometer-medical-aps","affectedVersions":[{"vendor":"Radiometer Medical Aps","product":"ABL90 FLEX and ABL90 FLEX PLUS Analyzers","versions":["Application software versions < 3.5MR11 with Windows 7, Windows XP operating systems"]},{"vendor":"Radiometer Medical Aps","product":"ABL800 BASIC and ABL800 FLEX Analyzers","versions":["Application software versions < 6.20MR2 with Windows 7, Windows XP operating systems"]},{"vendor":"Radiometer Medical Aps","product":"AQT90 FLEX Analyzers","versions":["Application software versions <= 8.13 MR2 with Windows 7, Windows XP operating systems"]}],"fixedVersions":[{"vendor":"Radiometer Medical Aps","product":"ABL90 FLEX and ABL90 FLEX PLUS Analyzers","versions":["Application software versions >= 3.5MR11 with Windows 10 operating system"]},{"vendor":"Radiometer Medical Aps","product":"ABL800 BASIC and ABL800 FLEX Analyzers","versions":["Application software versions >= 6.20MR2 with Windows 10 operating system"]},{"vendor":"Radiometer Medical Aps","product":"AQT90 FLEX Analyzers","versions":["Application software versions >= 8.13 MR2 with Windows 10 operating system"]}],"solutions":{"items":["Customers should ensure the following: • The network is secure, and access follows best practices. Local Radiometer representatives will contact all affected customers to discuss a permanent solution."],"from":"CVE.org CNA","provenance":"source"},"workarounds":{"items":["If the network is not considered secure, please remove the analyzer from the network."],"from":"CVE.org CNA","provenance":"source"},"capec":[{"id":"CAPEC-555","name":"Remote Services with Stolen Credentials"},{"id":"CAPEC-653","name":"Use of Known Operating System Credentials"}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2025-12-17T14:40:30.048229Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2025-203895","exploited":false,"provenance":"source"}}