{"id":"CVE-2025-15256","published":"2025-12-30T16:32:06Z","modified":"2026-02-24T06:18:04Z","title":"Edimax BR-6208AC Web-based Configuration formStaDrvSetup command injection","vendor":"Edimax","product":"BR-6208AC","tier":"tail","description":{"text":"A vulnerability was identified in Edimax BR-6208AC 1.02/1.03. Affected is the function formStaDrvSetup of the file /goform/formStaDrvSetup of the component Web-based Configuration Interface. The manipulation of the argument rootAPmac leads to command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. Edimax confirms this issue: \"The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security.\" This vulnerability only affects products that are no longer supported by the maintainer.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.3,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.04831,"percentile":0.92764,"provenance":"source"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"},{"id":"CWE-74","name":"Improper Neutralization of Special Elements in Output Used by a Downstream Component"}],"references":[{"url":"https://vuldb.com/?id.338646","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.338646","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.722014","tags":["third-party-advisory"]},{"url":"https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_1-02-Command-Injection-Vulnerability-in-Web-formStaDrvSetup-handler-2d2b5c52018a803ebd91c200b3e2925b?source=copy_link","tags":["exploit"]},{"url":"https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_1-02-Command-Injection-Vulnerability-in-Web-formStaDrvSetup-handler-2d2b5c52018a803ebd91c200b3e2925b","tags":["exploit"]}],"priority":{"score":28.7,"factors":[{"name":"EPSS percentile","points":18.55},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":5.11}]},"vendorSlug":"edimax","affectedVersions":[{"vendor":"Edimax","product":"BR-6208AC","versions":["1.02","1.03"]}],"ssvc":{"exploitation":"poc","automatable":"yes","technicalImpact":"partial","timestamp":"2025-12-30T18:09:24.781917Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"A command injection flaw exists in the Web-based Configuration Interface of the Edimax BR-6208AC, specifically in the formStaDrvSetup function at /goform/formStaDrvSetup, where the rootAPmac argument is not properly neutralised. An attacker with network access can exploit it without authentication or user interaction to inject and run commands on the device.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:19:06Z"},"euvd":{"id":"EUVD-2025-205807","exploited":false,"provenance":"source"},"exploitRefs":["https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_1-02-Command-Injection-Vulnerability-in-Web-formStaDrvSetup-handler-2d2b5c52018a803ebd91c200b3e2925b?source=copy_link","https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_1-02-Command-Injection-Vulnerability-in-Web-formStaDrvSetup-handler-2d2b5c52018a803ebd91c200b3e2925b"]}