{"id":"CVE-2025-15257","published":"2025-12-30T17:02:06Z","modified":"2026-02-24T06:18:16Z","title":"Edimax BR-6208AC Web-based Configuration formRoute command injection","vendor":"Edimax","product":"BR-6208AC","tier":"tail","description":{"text":"A security flaw has been discovered in Edimax BR-6208AC 1.02/1.03. Affected by this vulnerability is the function formRoute of the file /gogorm/formRoute of the component Web-based Configuration Interface. The manipulation of the argument strIp/strMask/strGateway results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks. Edimax confirms this issue: \"The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security.\" This vulnerability only affects products that are no longer supported by the maintainer.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.3,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.0644,"percentile":0.94494,"provenance":"source"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"},{"id":"CWE-74","name":"Improper Neutralization of Special Elements in Output Used by a Downstream Component"}],"references":[{"url":"https://vuldb.com/?id.338647","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.338647","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.722426","tags":["third-party-advisory"]},{"url":"https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_1-02-Command-Injection-Vulnerability-in-Web-formRoute-handler-2d3b5c52018a805983d3cf0780b28407?source=copy_link","tags":["exploit"]}],"priority":{"score":29.0,"factors":[{"name":"EPSS percentile","points":18.9},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":5.11}]},"vendorSlug":"edimax","affectedVersions":[{"vendor":"Edimax","product":"BR-6208AC","versions":["1.02","1.03"]}],"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial","timestamp":"2025-12-30T17:44:03.413501Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"A command injection flaw exists in the formRoute function (/gogorm/formRoute) of the Web-based Configuration Interface in the Edimax BR-6208AC 1.02/1.03, where the strIp, strMask and strGateway arguments are not properly neutralised. An attacker with network access can exploit this remotely, without authentication or user interaction, to inject commands; the default configuration is assumed as the only condition, since no other prerequisites are stated.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:18:11Z"},"euvd":{"id":"EUVD-2025-205833","exploited":false,"provenance":"source"},"exploitRefs":["https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_1-02-Command-Injection-Vulnerability-in-Web-formRoute-handler-2d3b5c52018a805983d3cf0780b28407?source=copy_link"]}