{"id":"CVE-2025-23403","published":"2025-02-11T10:29:04Z","modified":"2025-04-08T08:22:26Z","title":"A vulnerability has been identified in SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions)","vendor":"Siemens","product":"SIMATIC IPC DiagBase","tier":"tail","description":{"text":"A vulnerability has been identified in SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions). The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into the system leading to privilege escalation or bypassing endpoint protection and other security measures.","provenance":"source","from":"CVE.org"},"cvss":{"score":7,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00148,"percentile":0.04109,"provenance":"source"},"cwes":[{"id":"CWE-732","name":"Incorrect Permission Assignment for Critical Resource"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-369369.html","tags":[]}],"priority":{"score":5.7,"factors":[{"name":"EPSS percentile","points":0.82},{"name":"CVSS severity","points":4.9}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SIMATIC IPC DiagBase","versions":["all versions"]},{"vendor":"Siemens","product":"SIMATIC IPC DiagMonitor","versions":["all versions"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2025-02-11T16:24:17.910042Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2025-3162","exploited":false,"provenance":"source"}}