{"id":"CVE-2025-27093","published":"2025-10-28T19:29:16Z","modified":"2025-10-29T17:43:54Z","title":"Sliver does not restricted traffic between Wireguard clients.","vendor":"BishopFox","product":"sliver","tier":"tail","description":{"text":"Sliver is a command and control framework that uses a custom Wireguard netstack. In versions 1.5.43 and earlier, and in development version 1.6.0-dev, the netstack does not limit traffic between Wireguard clients. This allows clients to communicate with each other unrestrictedly, potentially enabling leaked or recovered keypairs to be used to attack operators or allowing port forwardings to be accessible from other implants.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00415,"percentile":0.27401,"provenance":"source"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"references":[{"url":"https://github.com/BishopFox/sliver/security/advisories/GHSA-q8j9-34qf-7vq7","tags":["x_refsource_CONFIRM"]},{"url":"https://github.com/BishopFox/sliver/commit/8e5c5f14506d6d60ebb3362e6b9857ab1e0d76ff","tags":["x_refsource_MISC"]},{"url":"https://github.com/BishopFox/sliver/commit/9122878cbbcae543eb8210f616550382af2065fd","tags":["x_refsource_MISC"]}],"priority":{"score":9.9,"factors":[{"name":"EPSS percentile","points":5.48},{"name":"CVSS severity","points":4.41}]},"vendorSlug":"bishopfox","affectedVersions":[{"vendor":"BishopFox","product":"sliver","versions":["<= 1.5.43"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2025-10-29T17:43:49.558008Z","from":"CISA ADP","provenance":"source"},"affected":[{"ecosystem":"Go","package":"github.com/BishopFox/sliver","vulnerableRanges":["<1.5.44"],"patched":["1.5.44"],"from":["GHSA-q8j9-34qf-7vq7","GO-2025-4079"],"provenance":"source"}],"summary":{"text":"Sliver, a command and control framework from BishopFox, fails to restrict traffic between Wireguard clients on its custom Wireguard netstack, in versions 1.5.43 and earlier and in the 1.6.0-dev development build. An attacker who holds a leaked or recovered Wireguard keypair, or who controls an implant, can reach other clients directly, which could be used to attack operators or to access port forwardings exposed by other implants, and this requires user interaction.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-20T22:09:37Z"},"euvd":{"id":"EUVD-2025-36543","exploited":false,"provenance":"source"},"lineage":{"familyId":"fam-bishopfox-sliver-cve-2024-41111","children":[{"from":"CVE-2025-27093","to":"CVE-2026-25791","relation":"related","confidence":"medium","kind":"lineage","evidence":[{"kind":"same-code","provenance":"machine","files":["server/c2/jobs.go"],"commits":["https://github.com/BishopFox/sliver/commit/8e5c5f14506d6d60ebb3362e6b9857ab1e0d76ff","https://github.com/BishopFox/sliver/commit/9122878cbbcae543eb8210f616550382af2065fd","https://github.com/BishopFox/sliver/commit/2b65089b27c553e79e69f1067cad1339e4f3d937"],"basis":"shared function","functions":["StartWGListenerJob"]}]}],"packageHistory":[{"cve":"CVE-2025-27093","published":"2025-10-28","fixed":"1.5.44","kev":false},{"cve":"CVE-2026-77622","published":"2026-11-05","fixed":"1.7.6","kev":false,"link":{"from":"CVE-2025-27093","to":"CVE-2026-77622","relation":"successor","confidence":"low","kind":"sequence","evidence":[{"kind":"version-step","provenance":"source","package":"Go:github.com/BishopFox/sliver","fromFixed":"1.5.44","toFixed":"1.7.6","daysApart":373}]}}],"package":"Go:github.com/BishopFox/sliver"}}