{"id":"CVE-2025-27253","published":"2025-03-10T09:04:34Z","modified":"2025-10-07T14:16:49Z","title":"A CWE-15 \"External Control of System or Configuration Setting\" in GE Vernova UR IED family devices from version 7.0 up…","vendor":"GE Vernova","product":"N60 multilin","tier":"tail","description":{"text":"A CWE-15 \"External Control of System or Configuration Setting\" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.1,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00234,"percentile":0.14543,"provenance":"source"},"cwes":[{"id":"CWE-15","name":"External Control of System or Configuration Setting"}],"references":[{"url":"https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily&type=21&file=76","tags":[]},{"url":"https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-27253","tags":[]}],"priority":{"score":7.2,"factors":[{"name":"EPSS percentile","points":2.91},{"name":"CVSS severity","points":4.27}]},"vendorSlug":"ge-vernova","affectedVersions":[{"vendor":"GE Vernova","product":"N60 multilin","versions":[">= 7.0, <= 8.60"]},{"vendor":"GE Vernova","product":"B30 Multilin","versions":[">= 7.0, <= 8.60"]},{"vendor":"GE Vernova","product":"B90 Multilin","versions":[">= 7.0, <= 8.60"]},{"vendor":"GE Vernova","product":"C30 Multilin","versions":[">= 7.0, <= 8.60"]},{"vendor":"GE Vernova","product":"C60 Multilin","versions":[">= 7.0, <= 8.60"]},{"vendor":"GE Vernova","product":"C70 Multilin","versions":[">= 7.0, <= 8.60"]},{"vendor":"GE Vernova","product":"C95 Multilin","versions":[">= 7.0, <= 8.60"]},{"vendor":"GE Vernova","product":"D30 Multilin","versions":[">= 7.0, <= 8.60"]},{"vendor":"GE Vernova","product":"D60 Multilin","versions":[">= 7.0, <= 8.60"]},{"vendor":"GE Vernova","product":"F35 Multilin","versions":[">= 7.0, <= 8.60"]}],"capec":[{"id":"CAPEC-1","name":"Accessing Functionality Not Properly Constrained by ACLs"}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2025-03-10T15:33:39.489617Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2025-7757","exploited":false,"provenance":"source"}}