{"id":"CVE-2025-28371","published":"2025-05-19T00:00:00Z","modified":"2025-05-19T16:00:16Z","title":"EnGenius ENH500 AP 2T2R V3.0 FW3.7.22 is vulnerable to Incorrect Access Control via the password change function","vendor":null,"product":null,"tier":"tail","description":{"text":"EnGenius ENH500 AP 2T2R V3.0 FW3.7.22 is vulnerable to Incorrect Access Control via the password change function. The device fails to validate the current password, allowing an attacker to submit a password change request with an invalid current password and set a new password.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.5,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L","provenance":"source","from":"CISA ADP Vulnrichment"},"epss":{"score":0.00788,"percentile":0.52753,"provenance":"source"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"references":[{"url":"https://drive.google.com/file/d/1kQFOyFQYycKynIBjbU8bMx2gYTG3Bxi2/view?usp=sharing","tags":[]},{"url":"https://pastebin.com/raw/hziq1nGH","tags":[]},{"url":"https://pastebin.com/raw/EnL1XT2n","tags":[]}],"priority":{"score":15.1,"factors":[{"name":"EPSS percentile","points":10.55},{"name":"CVSS severity","points":4.55}]},"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2025-05-19T15:59:05.930655Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2025-15703","exploited":false,"provenance":"source"}}