{"id":"CVE-2025-30042","published":"2026-03-02T11:14:46Z","modified":"2026-03-02T13:21:10Z","title":"Session generation possible with certificate number only","vendor":"CGM","product":"CGM CLININET","tier":"tail","description":{"text":"The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key.","provenance":"source","from":"CVE.org"},"cvss":{"score":9,"severity":"CRITICAL","version":"4.0","vector":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00157,"percentile":0.02536,"provenance":"source"},"cwes":[{"id":"CWE-603","name":"Use of Client-Side Authentication"}],"references":[{"url":"https://cert.pl/en/posts/2026/03/CVE-2025-10350/","tags":["third-party-advisory"]},{"url":"https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html","tags":["product"]}],"priority":{"score":6.8,"factors":[{"name":"EPSS percentile","points":0.51},{"name":"CVSS severity","points":6.3}]},"vendorSlug":"cgm","affectedVersions":[{"vendor":"CGM","product":"CGM CLININET","versions":["< 2025.MS2"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2026-03-02T13:20:54.724155Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2025-208147","exploited":false,"provenance":"source"}}