{"id":"CVE-2025-40569","published":"2025-06-10T15:17:33Z","modified":"2026-01-13T09:44:00Z","title":"A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328…","vendor":"Siemens","product":"RUGGEDCOM RST2428P","tier":"tail","description":{"text":"A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The \"Load Configuration from Local PC\" functionality in the web interface of affected products contains a race condition vulnerability. This could allow an authenticated remote attacker to make the affected product load an attacker controlled configuration instead of the legitimate one. Successful exploitation requires that a legitimate administrator invokes the functionality and the attacker wins the race condition.","provenance":"source","from":"CVE.org"},"cvss":{"score":4.8,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00298,"percentile":0.23004,"provenance":"source"},"cwes":[{"id":"CWE-362","name":"Concurrent Execution using Shared Resource with Improper Synchronization"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-693776.html","tags":[]}],"priority":{"score":8.0,"factors":[{"name":"EPSS percentile","points":4.6},{"name":"CVSS severity","points":3.36}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"RUGGEDCOM RST2428P","versions":["< V3.2"]},{"vendor":"Siemens","product":"SCALANCE XCH328","versions":["< V3.2"]},{"vendor":"Siemens","product":"SCALANCE XCM324","versions":["< V3.2"]},{"vendor":"Siemens","product":"SCALANCE XCM328","versions":["< V3.2"]},{"vendor":"Siemens","product":"SCALANCE XCM332","versions":["< V3.2"]},{"vendor":"Siemens","product":"SCALANCE XRH334 (24 V DC, 8xFO, CC)","versions":["< V3.2"]},{"vendor":"Siemens","product":"SCALANCE XRM334 (230 V AC, 12xFO)","versions":["< V3.2"]},{"vendor":"Siemens","product":"SCALANCE XRM334 (230 V AC, 8xFO)","versions":["< V3.2"]},{"vendor":"Siemens","product":"SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)","versions":["< V3.2"]},{"vendor":"Siemens","product":"SCALANCE XRM334 (24 V DC, 12xFO)","versions":["< V3.2"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2025-06-10T17:11:03.268317Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2025-17679","exploited":false,"provenance":"source"}}