{"id":"CVE-2025-40582","published":"2025-05-13T09:39:10Z","modified":"2026-09-08T08:11:15Z","title":"A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V2.1 HF0 with SINEMA…","vendor":"Siemens","product":"SCALANCE LPE9403","tier":"tail","description":{"text":"A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V2.1 HF0 with SINEMA Remote Connect Edge Client installed). Affected devices do not properly sanitize configuration parameters.\r\nThis could allow a non-privileged local attacker to execute root commands on the device.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.8,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00288,"percentile":0.13933,"provenance":"source"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-327438.html","tags":[]}],"priority":{"score":8.2,"factors":[{"name":"EPSS percentile","points":2.79},{"name":"CVSS severity","points":5.46}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SCALANCE LPE9403","versions":["< V2.1 HF0"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2025-05-13T13:12:22.843576Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2025-14664","exploited":false,"provenance":"source"}}