{"id":"CVE-2025-40584","published":"2025-08-12T11:17:02Z","modified":"2025-10-14T09:15:12Z","title":"A vulnerability has been identified in SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions)…","vendor":"Siemens","product":"SIMOTION SCOUT TIA V5.4","tier":"tail","description":{"text":"A vulnerability has been identified in SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions < V5.7 SP1 HF1), SIMOTION SCOUT V5.4 (All versions), SIMOTION SCOUT V5.5 (All versions), SIMOTION SCOUT V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT V5.7 (All versions < V5.7 SP1 HF1), SINAMICS STARTER V5.5 (All versions), SINAMICS STARTER V5.6 (All versions), SINAMICS STARTER V5.7 (All versions < V5.7 HF2). The affected application contains a XML External Entity Injection (XXE) vulnerability while parsing specially crafted XML files. This could allow an attacker to read arbitrary files in the system.","provenance":"source","from":"CVE.org"},"cvss":{"score":5.5,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00291,"percentile":0.14208,"provenance":"source"},"cwes":[{"id":"CWE-611","name":"Improper Restriction of XML External Entity Reference"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-186293.html","tags":[]}],"priority":{"score":6.7,"factors":[{"name":"EPSS percentile","points":2.84},{"name":"CVSS severity","points":3.85}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SIMOTION SCOUT TIA V5.4","versions":["all versions"]},{"vendor":"Siemens","product":"SIMOTION SCOUT TIA V5.5","versions":["all versions"]},{"vendor":"Siemens","product":"SIMOTION SCOUT TIA V5.6","versions":["< V5.6 SP1 HF7"]},{"vendor":"Siemens","product":"SIMOTION SCOUT TIA V5.7","versions":["< V5.7 SP1 HF1"]},{"vendor":"Siemens","product":"SIMOTION SCOUT V5.4","versions":["all versions"]},{"vendor":"Siemens","product":"SIMOTION SCOUT V5.5","versions":["all versions"]},{"vendor":"Siemens","product":"SIMOTION SCOUT V5.6","versions":["< V5.6 SP1 HF7"]},{"vendor":"Siemens","product":"SIMOTION SCOUT V5.7","versions":["< V5.7 SP1 HF1"]},{"vendor":"Siemens","product":"SINAMICS STARTER V5.5","versions":["all versions"]},{"vendor":"Siemens","product":"SINAMICS STARTER V5.6","versions":["all versions"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2025-08-12T13:30:27.626406Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2025-24246","exploited":false,"provenance":"source"}}