{"id":"CVE-2025-40737","published":"2025-07-08T10:34:55Z","modified":"2025-07-08T13:29:14Z","title":"A vulnerability has been identified in SINEC NMS (All versions < V4.0)","vendor":"Siemens","product":"SINEC NMS","tier":"tail","description":{"text":"A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application does not properly validate file paths when extracting uploaded ZIP files. This could allow an attacker to write arbitrary files to restricted locations and potentially execute code with elevated privileges (ZDI-CAN-26571).","provenance":"source","from":"CVE.org"},"cvss":{"score":8.8,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.13751,"percentile":0.96596,"provenance":"source"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-078892.html","tags":[]}],"priority":{"score":25.5,"factors":[{"name":"EPSS percentile","points":19.32},{"name":"CVSS severity","points":6.16}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SINEC NMS","versions":["< V4.0"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2025-07-08T13:29:05.266799Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"A path-validation flaw in Siemens SINEC NMS (all versions before V4.0) lies in how the application extracts uploaded ZIP files, where file paths are not properly checked against a restricted directory. An attacker who can reach the application and has a low-privileged account can exploit this without any user interaction to write arbitrary files to protected locations and potentially run code with elevated privileges.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T07:23:43Z"},"euvd":{"id":"EUVD-2025-20432","exploited":false,"provenance":"source"}}