{"id":"CVE-2025-40830","published":"2025-12-09T10:44:32Z","modified":"2025-12-09T15:45:31Z","title":"A vulnerability has been identified in SINEC Security Monitor (All versions < V4.10.0)","vendor":"Siemens","product":"SINEC Security Monitor","tier":"tail","description":{"text":"A vulnerability has been identified in SINEC Security Monitor (All versions < V4.10.0). The affected application does not have proper authorization checks for the file_transfer feature in ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to read or write to any file on server or sensor.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.7,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00202,"percentile":0.05735,"provenance":"source"},"cwes":[{"id":"CWE-285","name":"Improper Authorization"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-882673.html","tags":[]}],"priority":{"score":5.8,"factors":[{"name":"EPSS percentile","points":1.15},{"name":"CVSS severity","points":4.69}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"SINEC Security Monitor","versions":["< V4.10.0"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2025-12-09T15:45:06.041637Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2025-201922","exploited":false,"provenance":"source"}}