{"id":"CVE-2025-41224","published":"2025-07-08T10:35:09Z","modified":"2025-07-08T20:31:27Z","title":"A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.10.0), RUGGEDCOM RMC8388NC V5.X (All…","vendor":"Siemens","product":"RUGGEDCOM RMC8388 V5.X","tier":"tail","description":{"text":"A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.10.0), RUGGEDCOM RMC8388NC V5.X (All versions < V5.10.0), RUGGEDCOM RS416NCv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416PNCv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.0), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900GNC(32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900NC(32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100NC(32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100PNC (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2288NC V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300NC V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300PNC V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488NC V5.X (All versions < V5.10.0), RUGGEDCOM RSG907R (All versions < V5.10.0), RUGGEDCOM RSG908C (All versions < V5.10.0), RUGGEDCOM RSG909R (All versions < V5.10.0), RUGGEDCOM RSG910C (All versions < V5.10.0), RUGGEDCOM RSG920P V5.X (All versions < V5.10.0), RUGGEDCOM RSG920PNC V5.X (All versions < V5.10.0), RUGGEDCOM RSL910 (All versions < V5.10.0), RUGGEDCOM RSL910NC (All versions < V5.10.0), RUGGEDCOM RST2228 (All versions < V5.10.0), RUGGEDCOM RST2228P (All versions < V5.10.0), RUGGEDCOM RST916C (All versions < V5.10.0), RUGGEDCOM RST916P (All versions < V5.10.0). The affected products do not properly enforce interface access restrictions when changing from management to non-management interface configurations until a system reboot occurs, despite configuration being saved. This could allow an attacker with network access and credentials to gain access to device through non-management and maintain SSH access to the device until reboot.","provenance":"source","from":"CVE.org"},"cvss":{"score":8.8,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00258,"percentile":0.17809,"provenance":"source"},"cwes":[{"id":"CWE-693","name":"Protection Mechanism Failure"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-083019.html","tags":[]}],"priority":{"score":9.7,"factors":[{"name":"EPSS percentile","points":3.56},{"name":"CVSS severity","points":6.16}]},"vendorSlug":"siemens","affectedVersions":[{"vendor":"Siemens","product":"RUGGEDCOM RMC8388 V5.X","versions":["< V5.10.0"]},{"vendor":"Siemens","product":"RUGGEDCOM RMC8388NC V5.X","versions":["< V5.10.0"]},{"vendor":"Siemens","product":"RUGGEDCOM RS416NCv2 V5.X","versions":["< V5.10.0"]},{"vendor":"Siemens","product":"RUGGEDCOM RS416PNCv2 V5.X","versions":["< V5.10.0"]},{"vendor":"Siemens","product":"RUGGEDCOM RS416Pv2 V5.X","versions":["< V5.10.0"]},{"vendor":"Siemens","product":"RUGGEDCOM RS416v2 V5.X","versions":["< V5.10.0"]},{"vendor":"Siemens","product":"RUGGEDCOM RS900 (32M) V5.X","versions":["< V5.10.0"]},{"vendor":"Siemens","product":"RUGGEDCOM RS900G (32M) V5.X","versions":["< V5.10.0"]},{"vendor":"Siemens","product":"RUGGEDCOM RS900GNC(32M) V5.X","versions":["< V5.10.0"]},{"vendor":"Siemens","product":"RUGGEDCOM RS900NC(32M) V5.X","versions":["< V5.10.0"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2025-07-08T20:31:21.314188Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2025-20424","exploited":false,"provenance":"source"}}