{"id":"CVE-2025-41451","published":"2025-08-22T02:40:46Z","modified":"2026-10-19T19:12:52Z","title":"Post-Authentication OS Command Injection RCE in Danfoss AK-SM8xxA Series","vendor":"Danfoss","product":"AK-SM8xxA Series","tier":"core","eol":null,"affectedVersions":[{"vendor":"Danfoss","product":"AK-SM8xxA Series","versions":["< 4.3.1"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"total","timestamp":"2026-10-19T19:12:30.691978Z","from":"CISA ADP","provenance":"source"},"description":{"text":"Improper neutralization of alarm-to-mail configuration fields used in an OS shell Command ('Command Injection') in Danfoss AK-SM8xxA Series prior to version 4.3.1, leading to a potential post-authenticated remote code execution on an attacked system.","provenance":"source","from":"CVE.org"},"summary":{"text":"The flaw is an OS command injection in the alarm-to-mail configuration fields of the Danfoss AK-SM8xxA Series, due to improper neutralization of special elements before they are passed to a shell. An attacker with network access and high-privilege authentication (and, per the vector, a high-complexity condition that requires a specific precondition or configuration) could inject operating system commands through those fields to achieve remote code execution on the affected device.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-20T06:28:18Z"},"cvss":{"score":8.7,"severity":"HIGH","version":"4.0","vector":"CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.01521,"percentile":0.74868,"date":"2026-11-25","provenance":"source"},"kev":null,"vulncheckKev":{"dateAdded":"2026-11-03","exploitedFirstSeen":"2026-11-03","ransomware":false,"evidence":[{"url":"https://github.com/enisaeu/CNW/blob/main/advisories/2026/CNW-2026-05_retail-incidents.md","date":"2026-11-03"}],"evidenceTotal":1,"provenance":"source"},"exploited":true,"otx":{"pulseCount":3,"pulses":[{"name":"European Refrigeration Systems Cyber Sabotage","url":"https://otx.alienvault.com/pulse/6af9337bfdc2f9e5b1f0084a","created":"2026-11-15"},{"name":"European Refrigeration Systems Cyber Sabotage","url":"https://otx.alienvault.com/pulse/6af6c512eff4af48c4b11a6b","created":"2026-11-13"},{"name":"Danfoss Refrigeration Hack Update – 4,980 Hosts Found Exposed to Internet","url":"https://otx.alienvault.com/pulse/6ace548e00c8b0b6657b943b","created":"2026-10-13"}],"provenance":"machine"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"references":[{"url":"https://www.danfoss.com/en/service-and-support/downloads/dcs/adap-kool-software/ak-sm-800a/#tab-overview","tags":[]},{"url":"https://github.com/msuiche/fromagegate","tags":["exploit"]}],"techniques":[],"reports":[],"affected":[],"advisories":[],"euvd":{"id":"EUVD-2025-25499","url":"https://euvd.enisa.europa.eu/vulnerability/EUVD-2025-25499","exploited":false,"exploitedSince":null,"provenance":"source"},"exploits":[],"exploitSources":null,"exploitRefs":["https://github.com/msuiche/fromagegate"],"flow":[],"timeline":[{"date":"2025-08-22","kind":"published","label":"Published (CVE.org)","url":"https://www.cve.org/CVERecord?id=CVE-2025-41451","provenance":"source"},{"date":"2026-11-03","kind":"exploited-reported","label":"Exploitation first reported (VulnCheck KEV evidence)","url":"https://github.com/enisaeu/CNW/blob/main/advisories/2026/CNW-2026-05_retail-incidents.md","provenance":"source"}],"speed":{"daysToPublicExploit":null,"firstExploitFrom":null,"daysToKev":null},"priority":{"score":72.4,"factors":[{"name":"In a KEV catalog","points":35.0,"detail":"listed in VulnCheck KEV"},{"name":"Recent KEV listing","points":10.0,"detail":"added 22 days ago"},{"name":"Known ransomware use","points":0.0,"detail":"not known"},{"name":"EPSS percentile","points":14.97,"detail":"percentile 0.7487"},{"name":"Named in threat reports","points":0.0,"detail":"0 reports"},{"name":"Public exploit code","points":5.0,"detail":"1 reference tagged Exploit"},{"name":"Mentioned in OTX pulses","points":1.37,"detail":"3 pulses"},{"name":"CVSS severity","points":6.09,"detail":"base score 8.7"},{"name":"End-of-life product","points":0.0,"detail":"supported or unknown"}]}}