{"id":"CVE-2025-41690","published":"2025-09-02T08:12:13Z","modified":"2025-09-02T13:48:59Z","title":"Endress+Hauser: Proline 10 Maintenance credentials may be exposed under certain conditions","vendor":"Endress+Hauser","product":"Promag 10 with HART","tier":"tail","description":{"text":"A low-privileged attacker in bluetooth range may be able to access the password of a higher-privilege user (Maintenance) by viewing the device’s event log. This vulnerability could allow the Operator to authenticate as the Maintenance user, thereby gaining unauthorized access to sensitive configuration settings and the ability to modify device parameters.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.4,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00398,"percentile":0.25625,"provenance":"source"},"cwes":[{"id":"CWE-532","name":"Insertion of Sensitive Information into Log File"}],"references":[{"url":"https://certvde.com/en/advisories/VDE-2025-068","tags":[]}],"priority":{"score":10.3,"factors":[{"name":"EPSS percentile","points":5.12},{"name":"CVSS severity","points":5.18}]},"vendorSlug":"endress-hauser","affectedVersions":[{"vendor":"Endress+Hauser","product":"Promag 10 with HART","versions":["< 01.00.06"]},{"vendor":"Endress+Hauser","product":"Promag 10 with IO-Link","versions":["< 01.00.02"]},{"vendor":"Endress+Hauser","product":"Promag 10 with Modbus","versions":["< 01.00.06"]},{"vendor":"Endress+Hauser","product":"Promass 10 with HART","versions":["< 01.00.06"]},{"vendor":"Endress+Hauser","product":"Promass 10 with IO-Link","versions":["< 01.00.02"]},{"vendor":"Endress+Hauser","product":"Promass 10 with Modbus","versions":["< 01.00.06"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2025-09-02T13:48:53.162675Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2025-26393","exploited":false,"provenance":"source"}}