{"id":"CVE-2025-53520","published":"2025-08-08T16:09:02Z","modified":"2025-08-08T19:12:44Z","title":"EG4 Electronics EG4 Inverters Download of Code Without Integrity Check","vendor":"EG4 Electronics","product":"EG4 12kPV","tier":"tail","description":{"text":"The affected product allows firmware updates to be downloaded from EG4's\n website, transferred via USB dongles, or installed through EG4's \nMonitoring Center (remote, cloud-connected interface) or via a serial \nconnection, and can install these files without integrity checks. The \nTTComp archive format used for the firmware is unencrypted and can be \nunpacked and altered without detection.","provenance":"source","from":"CVE.org"},"cvss":{"score":8.8,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00224,"percentile":0.13268,"provenance":"source"},"cwes":[{"id":"CWE-494","name":"Download of Code Without Integrity Check"}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-25-219-07","tags":[]},{"url":"https://eg4electronics.com/contact/","tags":[]}],"priority":{"score":8.8,"factors":[{"name":"EPSS percentile","points":2.65},{"name":"CVSS severity","points":6.16}]},"vendorSlug":"eg4-electronics","affectedVersions":[{"vendor":"EG4 Electronics","product":"EG4 12kPV","versions":["all versions"]},{"vendor":"EG4 Electronics","product":"EG4 18kPV","versions":["all versions"]},{"vendor":"EG4 Electronics","product":"EG4 Flex 21","versions":["all versions"]},{"vendor":"EG4 Electronics","product":"EG4 Flex 18","versions":["all versions"]},{"vendor":"EG4 Electronics","product":"EG4 6000XP","versions":["all versions"]},{"vendor":"EG4 Electronics","product":"EG4 12000XP","versions":["all versions"]},{"vendor":"EG4 Electronics","product":"EG4 GridBoss","versions":["all versions"]}],"workarounds":{"items":["EG4 has acknowledged the vulnerabilities and is actively working on a fix, including new hardware expected to release by October 15, 2025. Until then, EG4 will actively monitor all installed systems and work with affected users on a case-by-case basis if anomalies are observed. For more information, contact EG4. https://eg4electronics.com/contact/"],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2025-08-08T19:12:34.163280Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2025-23995","exploited":false,"provenance":"source"}}