{"id":"CVE-2025-5946","published":"2025-10-14T14:29:00Z","modified":"2025-10-14T16:03:12Z","title":"RCE via the poller reload feature available only to user with high privilege","vendor":"Centreon","product":"Infra Monitoring","tier":"tail","description":{"text":"Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection.\nOn the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.2,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.13508,"percentile":0.96535,"provenance":"source"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"references":[{"url":"https://github.com/centreon/centreon/releases","tags":["release-notes"]},{"url":"https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-5946-centreon-web-all-versions-high-severity-5104","tags":["vendor-advisory"]}],"priority":{"score":29.3,"factors":[{"name":"EPSS percentile","points":19.31},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":5.04}]},"exploitSources":{"metasploit":[{"name":"Centreon authenticated command injection leading to RCE via broker engine \"reload\" parameter","module":"exploit/linux/http/centreon_auth_rce_cve_2025_5946","type":"exploit","disclosureDate":"2025-09-24","url":"https://github.com/rapid7/metasploit-framework/blob/master/modules/exploits/linux/http/centreon_auth_rce_cve_2025_5946.rb"}],"first":{"date":"2025-09-24","source":"Metasploit","url":"https://github.com/rapid7/metasploit-framework/blob/master/modules/exploits/linux/http/centreon_auth_rce_cve_2025_5946.rb"},"provenance":"source"},"vendorSlug":"centreon","affectedVersions":[{"vendor":"Centreon","product":"Infra Monitoring","versions":[">= 24.10.0, < 24.10.13",">= 24.04.0, < 24.04.18",">= 23.10.0, < 23.10.28"]}],"capec":[{"id":"CAPEC-88","name":"OS Command Injection"}],"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"total","timestamp":"2025-10-14T16:03:02.831678Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"A command injection flaw in the poller reload setup of the configuration modules in Centreon Infra Monitoring allows a user to concatenate custom instructions into the poller reload command via the poller parameters page. An attacker needs an account with high privileges and network access to the product, with no user interaction required.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:03:10Z"},"euvd":{"id":"EUVD-2025-34208","exploited":false,"provenance":"source"}}