{"id":"CVE-2025-66052","published":"2026-01-09T11:54:16Z","modified":"2026-01-09T12:51:10Z","title":"Command injection in Vivotek IP7137 cameras","vendor":"Vivotek","product":"IP7137","tier":"tail","description":{"text":"Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter \"system_ntpIt\" used by \"/cgi-bin/admin/setparam.cgi\" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default, \nThe vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.","provenance":"source","from":"CVE.org"},"cvss":{"score":8.6,"severity":"HIGH","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.01491,"percentile":0.74742,"provenance":"source"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"references":[{"url":"https://cert.pl/posts/2026/01/CVE-2025-66049","tags":["third-party-advisory"]}],"priority":{"score":21.0,"factors":[{"name":"EPSS percentile","points":14.95},{"name":"CVSS severity","points":6.02}]},"vendorSlug":"vivotek","affectedVersions":[{"vendor":"Vivotek","product":"IP7137","versions":["0200a"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2026-01-09T12:50:56.686031Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-1748","exploited":false,"provenance":"source"}}