{"id":"CVE-2025-6899","published":"2025-06-30T08:32:05Z","modified":"2025-06-30T17:34:29Z","title":"D-Link DI-7300G+/DI-8200G msp_info.htm os command injection","vendor":"D-Link","product":"DI-7300G+","tier":"tail","description":{"text":"A vulnerability, which was classified as critical, was found in D-Link DI-7300G+ and DI-8200G 17.12.20A1/19.12.25A1. This affects an unknown part of the file msp_info.htm. The manipulation of the argument flag/cmd/iface leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.0477,"percentile":0.92118,"provenance":"source"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"references":[{"url":"https://vuldb.com/?id.314391","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.314391","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.604444","tags":["third-party-advisory"]},{"url":"https://github.com/2664521593/mycve/blob/main/D-Link_DI/CJ_IN_DLink_4_en.pdf","tags":["exploit"]},{"url":"https://www.dlink.com/","tags":["product"]}],"priority":{"score":27.8,"factors":[{"name":"EPSS percentile","points":18.42},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":4.41}]},"vendorSlug":"d-link","affectedVersions":[{"vendor":"D-Link","product":"DI-7300G+","versions":["17.12.20A1","19.12.25A1"]},{"vendor":"D-Link","product":"DI-8200G","versions":["17.12.20A1","19.12.25A1"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2025-06-30T17:32:01.074018Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"An OS command injection flaw exists in the msp_info.htm component of D-Link DI-7300G+ and DI-8200G devices, where the flag/cmd/iface argument is not properly neutralised before being used in a system command. An attacker with low-privileged authentication can reach the device remotely over the network, without any user interaction, to inject operating system commands through that argument.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:19:38Z"},"euvd":{"id":"EUVD-2025-19521","exploited":false,"provenance":"source"},"exploitRefs":["https://github.com/2664521593/mycve/blob/main/D-Link_DI/CJ_IN_DLink_4_en.pdf"]}