{"id":"CVE-2025-8823","published":"2025-08-11T01:05:04Z","modified":"2025-08-12T15:08:13Z","title":"Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setDeviceName os command injection","vendor":"Linksys","product":"RE6250","tier":"tail","description":{"text":"A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function setDeviceName of the file /goform/setDeviceName. The manipulation of the argument DeviceName leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.05678,"percentile":0.93172,"provenance":"source"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"references":[{"url":"https://vuldb.com/?id.319357","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.319357","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.626687","tags":["third-party-advisory"]},{"url":"https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_57/57.md","tags":["related"]},{"url":"https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_57/57.md#poc","tags":["exploit"]},{"url":"https://www.linksys.com/","tags":["product"]}],"priority":{"score":28.0,"factors":[{"name":"EPSS percentile","points":18.63},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":4.41}]},"vendorSlug":"linksys","affectedVersions":[{"vendor":"Linksys","product":"RE6250","versions":["20250801"]},{"vendor":"Linksys","product":"RE6300","versions":["20250801"]},{"vendor":"Linksys","product":"RE6350","versions":["20250801"]},{"vendor":"Linksys","product":"RE6500","versions":["20250801"]},{"vendor":"Linksys","product":"RE7000","versions":["20250801"]},{"vendor":"Linksys","product":"RE9000","versions":["20250801"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2025-08-12T15:08:08.222328Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"A command injection flaw exists in the setDeviceName function, reached via the /goform/setDeviceName endpoint, in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 range extenders, where the DeviceName argument is not properly neutralised before being used in an operating system command. An attacker who can reach the device over the network with low privileges (the attack vector is remote, with no user interaction required) can inject OS commands through DeviceName, and a public exploit is available.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:19:18Z"},"euvd":{"id":"EUVD-2025-24103","exploited":false,"provenance":"source"},"exploitRefs":["https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_57/57.md#poc"]}