{"id":"CVE-2025-8827","published":"2025-08-11T03:02:06Z","modified":"2025-08-12T14:21:14Z","title":"Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_inspect_cross_band os command injection","vendor":"Linksys","product":"RE6250","tier":"tail","description":{"text":"A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function um_inspect_cross_band of the file /goform/RP_setBasicAuto. The manipulation of the argument staticGateway leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.05678,"percentile":0.93173,"provenance":"source"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"references":[{"url":"https://vuldb.com/?id.319361","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.319361","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.626692","tags":["third-party-advisory"]},{"url":"https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md","tags":["related"]},{"url":"https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md#poc","tags":["exploit"]},{"url":"https://www.linksys.com/","tags":["product"]}],"priority":{"score":28.0,"factors":[{"name":"EPSS percentile","points":18.63},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":4.41}]},"vendorSlug":"linksys","affectedVersions":[{"vendor":"Linksys","product":"RE6250","versions":["20250801"]},{"vendor":"Linksys","product":"RE6300","versions":["20250801"]},{"vendor":"Linksys","product":"RE6350","versions":["20250801"]},{"vendor":"Linksys","product":"RE6500","versions":["20250801"]},{"vendor":"Linksys","product":"RE7000","versions":["20250801"]},{"vendor":"Linksys","product":"RE9000","versions":["20250801"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2025-08-12T14:21:11.472745Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"A flaw in the um_inspect_cross_band function of the /goform/RP_setBasicAuto component in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 extender firmware allows OS command injection through the staticGateway argument. An attacker with low-privilege authentication can exploit it remotely over the network, without user interaction, to run arbitrary operating system commands on the device.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:19:18Z"},"euvd":{"id":"EUVD-2025-24107","exploited":false,"provenance":"source"},"exploitRefs":["https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md#poc"]}