{"id":"CVE-2025-8828","published":"2025-08-11T03:32:05Z","modified":"2025-08-12T14:09:29Z","title":"Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setIpv6 ipv6cmd os command injection","vendor":"Linksys","product":"RE6250","tier":"tail","description":{"text":"A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected is the function ipv6cmd of the file /goform/setIpv6. The manipulation of the argument Ipv6PriDns/Ipv6SecDns/Ipv6StaticGateway/LanIpv6Addr/LanPrefixLen/pppoeUser/pppoePass/pppoeIdleTime/pppoeRedialPeriod/Ipv6in4_PrefixLen/LocalIpv6/RemoteIpv4/LanIPv6_Prefix/LanPrefixLen/ipv6to4Relay/ipv6rdRelay/tunrd_PrefixLen/wan_UseLinkLocal/Ipv6StaticIp/Ipv6PrefixLen leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.05678,"percentile":0.93172,"provenance":"source"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"references":[{"url":"https://vuldb.com/?id.319362","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.319362","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.626693","tags":["third-party-advisory"]},{"url":"https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_44/44.md","tags":["related"]},{"url":"https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_44/44.md#poc","tags":["exploit"]},{"url":"https://www.linksys.com/","tags":["product"]}],"priority":{"score":28.0,"factors":[{"name":"EPSS percentile","points":18.63},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":4.41}]},"vendorSlug":"linksys","affectedVersions":[{"vendor":"Linksys","product":"RE6250","versions":["20250801"]},{"vendor":"Linksys","product":"RE6300","versions":["20250801"]},{"vendor":"Linksys","product":"RE6350","versions":["20250801"]},{"vendor":"Linksys","product":"RE6500","versions":["20250801"]},{"vendor":"Linksys","product":"RE7000","versions":["20250801"]},{"vendor":"Linksys","product":"RE9000","versions":["20250801"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2025-08-12T14:09:26.315772Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"A command injection flaw exists in the ipv6cmd function of the /goform/setIpv6 component in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 range extenders, where several IPv6 and PPPoE parameters are passed unsanitised into operating system commands. An attacker with network access can exploit this remotely by supplying crafted values for these arguments, and the attack needs low-privilege authentication to the device.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:19:19Z"},"euvd":{"id":"EUVD-2025-24121","exploited":false,"provenance":"source"},"exploitRefs":["https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_44/44.md#poc"]}