{"id":"CVE-2025-8830","published":"2025-08-11T04:32:06Z","modified":"2025-08-11T20:29:35Z","title":"Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setWan sub_3517C os command injection","vendor":"Linksys","product":"RE6250","tier":"tail","description":{"text":"A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function sub_3517C of the file /goform/setWan. The manipulation of the argument Hostname leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","provenance":"source","from":"CVE.org"},"cvss":{"score":6.3,"severity":"MEDIUM","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.05678,"percentile":0.93173,"provenance":"source"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"references":[{"url":"https://vuldb.com/?id.319364","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.319364","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.626695","tags":["third-party-advisory"]},{"url":"https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_46/46.md","tags":["related"]},{"url":"https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_46/46.md#poc","tags":["exploit"]},{"url":"https://www.linksys.com/","tags":["product"]}],"priority":{"score":28.0,"factors":[{"name":"EPSS percentile","points":18.63},{"name":"Public exploit code","points":5.0},{"name":"CVSS severity","points":4.41}]},"vendorSlug":"linksys","affectedVersions":[{"vendor":"Linksys","product":"RE6250","versions":["20250801"]},{"vendor":"Linksys","product":"RE6300","versions":["20250801"]},{"vendor":"Linksys","product":"RE6350","versions":["20250801"]},{"vendor":"Linksys","product":"RE6500","versions":["20250801"]},{"vendor":"Linksys","product":"RE7000","versions":["20250801"]},{"vendor":"Linksys","product":"RE9000","versions":["20250801"]}],"ssvc":{"exploitation":"poc","automatable":"no","technicalImpact":"partial","timestamp":"2025-08-11T20:29:30.987889Z","from":"CISA ADP","provenance":"source"},"summary":{"text":"The Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 range-extender firmware contains an OS command injection flaw in the function sub_3517C of the /goform/setWan component, where the Hostname argument is not properly neutralised. An attacker with network access and low-privilege authentication can remotely inject operating system commands through that argument, and the attack requires no user interaction.","provenance":"ai","model":"claude-haiku-5-5","generatedAt":"2026-11-21T04:19:19Z"},"euvd":{"id":"EUVD-2025-24123","exploited":false,"provenance":"source"},"exploitRefs":["https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_46/46.md#poc"]}