{"id":"CVE-2025-9036","published":"2025-08-14T13:39:19Z","modified":"2025-08-14T15:05:37Z","title":"Rockwell Automation FactoryTalk® Action Manager v1.0.0 Runtime Vulnerability","vendor":"Rockwell Automation","product":"FactoryTalk® Action Manager","tier":"tail","description":{"text":"A security issue in the runtime event system allows unauthenticated connections to receive a reusable API token. This token is broadcasted over a WebSocket and can be intercepted by any local client listening on the connection.","provenance":"source","from":"CVE.org"},"cvss":{"score":8.5,"severity":"HIGH","version":"4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00186,"percentile":0.08383,"provenance":"source"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1740.html","tags":[]}],"priority":{"score":7.6,"factors":[{"name":"EPSS percentile","points":1.68},{"name":"CVSS severity","points":5.95}]},"vendorSlug":"rockwell-automation","affectedVersions":[{"vendor":"Rockwell Automation","product":"FactoryTalk® Action Manager","versions":["Version 1.0.0 or below"]}],"solutions":{"items":["1.01 and later"],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2025-08-14T14:01:56.242606Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2025-24814","exploited":false,"provenance":"source"}}