{"id":"CVE-2026-0647","published":"2026-06-16T14:20:12Z","modified":"2026-06-16T15:23:45Z","title":"Rockwell Automation FLEX I/O Dual-port EtherNet/IP Adapters – Multiple Vulnerabilities","vendor":"Rockwell Automation","product":"FLEX I/O EtherNet/IP Adapters","tier":"tail","description":{"text":"An improper authentication security issue exists within the 1794-AENTR adapter's embedded web server. The vulnerability allows an unauthenticated attacker to change the device's web interface password by sending a crafted HTTP GET request to a specific endpoint, without any prior authentication being required. If exploited, this could lead to unauthorized access, account takeover, and loss of the device’s embedded web server’s availability.","provenance":"source","from":"CVE.org"},"cvss":{"score":8.8,"severity":"HIGH","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00435,"percentile":0.38628,"provenance":"source"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1775.html","tags":[]}],"priority":{"score":13.9,"factors":[{"name":"EPSS percentile","points":7.73},{"name":"CVSS severity","points":6.16}]},"vendorSlug":"rockwell-automation","affectedVersions":[{"vendor":"Rockwell Automation","product":"FLEX I/O EtherNet/IP Adapters","versions":["2.012"]}],"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial","timestamp":"2026-06-16T15:23:37.954588Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-37122","exploited":false,"provenance":"source"}}