{"id":"CVE-2026-111731","published":"2026-10-29T15:39:02Z","modified":"2026-11-05T21:21:10Z","title":"Infinite loop when reading PDPortDataCheck record of subslot 0","vendor":"RT-Labs","product":"P-Net","tier":"tail","description":{"text":"P-Net before 1.0.3 enters an infinite loop when handling a read request for the PDPortDataCheck record with subslot 0 (whole module). The loop over the ports never advanced to the next port, so the request never completes and the device stops responding. A remote unauthenticated attacker can use this to cause a denial of service.","provenance":"source","from":"CVE.org"},"cvss":{"score":8.7,"severity":"HIGH","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00402,"percentile":0.35332,"provenance":"source"},"cwes":[{"id":"CWE-835","name":"Loop with Unreachable Exit Condition"}],"references":[{"url":"https://rt-labs.com/wp-content/uploads/2026/10/RRTL-261019-01.pdf","tags":[]}],"priority":{"score":13.2,"factors":[{"name":"EPSS percentile","points":7.07},{"name":"CVSS severity","points":6.09}]},"vendorSlug":"rt-labs","affectedVersions":[{"vendor":"RT-Labs","product":"P-Net","versions":["< 1.0.3"]}],"solutions":{"items":["Upgrade to P-Net 1.0.3 or later."],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial","timestamp":"2026-11-05T21:21:00.842401Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-113005","exploited":false,"provenance":"source"}}