{"id":"CVE-2026-111735","published":"2026-10-29T15:42:29Z","modified":"2026-11-05T21:23:14Z","title":"Integer underflow leads to out-of-bounds read in pf_cpm_c_data_ind()","vendor":"RT-Labs","product":"P-Net","tier":"tail","description":{"text":"P-Net before 1.0.3 contains an integer underflow in pf_cpm_c_data_ind(). When handling a received cyclic data frame while the consumer is in the FRUN or RUN state, the offset of the APDU status was computed as the frame length minus 4 using 16-bit arithmetic, without checking that the frame is long enough. A crafted short frame makes the offset wrap around, so the function reads outside the receive buffer. This can cause a crash (denial of service) or disclose memory content.","provenance":"source","from":"CVE.org"},"cvss":{"score":7.1,"severity":"HIGH","version":"4.0","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:H/SC:N/SI:N/SA:N","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00165,"percentile":0.05802,"provenance":"source"},"cwes":[{"id":"CWE-191","name":"Integer Underflow (Wrap or Wraparound)"},{"id":"CWE-125","name":"Out-of-bounds Read"}],"references":[{"url":"https://rt-labs.com/wp-content/uploads/2026/10/RRTL-261019-01.pdf","tags":[]}],"priority":{"score":6.1,"factors":[{"name":"EPSS percentile","points":1.16},{"name":"CVSS severity","points":4.97}]},"vendorSlug":"rt-labs","affectedVersions":[{"vendor":"RT-Labs","product":"P-Net","versions":["< 1.0.3"]}],"solutions":{"items":["Upgrade to P-Net 1.0.3 or later."],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial","timestamp":"2026-11-05T21:23:06.376150Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-113009","exploited":false,"provenance":"source"}}