{"id":"CVE-2026-11826","published":"2026-07-18T13:35:35Z","modified":"2026-11-03T20:26:44Z","title":"OpenPLC_v3 Heap-Based Buffer Overflow in Modbus Master getData()","vendor":"openplcproject","product":"OpenPLC_v3","tier":"tail","description":{"text":"OpenPLC_v3 contains a heap-based buffer overflow in the getData() function in webserver/core/modbus_master.cpp. getData() reads characters between two delimiters into a caller-supplied buffer with no size parameter and no bounds check. In parseConfig() the function is invoked with the 100-byte heap-allocated MB_device.dev_name field. An authenticated attacker with access to the OpenPLC web interface can send a crafted HTTP POST to the /modbus endpoint with an oversized device_name value; the value is persisted to mbconfig.cfg and parsed on load, overflowing dev_name and overwriting adjacent struct fields (protocol at offset 108, dev_address at offset 109, ip_port at offset 210). A 200-byte payload writes 100 bytes past the allocation. The result is heap corruption leading to runtime crash and denial of service of the PLC process control loop, with attacker-controlled overwrite of adjacent configuration fields. The upstream repository was archived on 2026-04-04 and no fix is expected; the vendor has confirmed the issue does not affect OpenPLC Runtime v4.","provenance":"source","from":"CVE.org"},"cvss":{"score":8.8,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.0075,"percentile":0.51118,"provenance":"source"},"cwes":[{"id":"CWE-122","name":"Heap-based Buffer Overflow"}],"references":[{"url":"https://gist.github.com/Shukhrat-03/5cf1825b72e485ef98a32958dfbc611a#security-vulnerability-report","tags":["technical-description"]},{"url":"https://github.com/thiagoralves/OpenPLC_v3/commit/b4702061dc14d1024856f71b4543298d77007b88","tags":["patch"]},{"url":"https://github.com/thiagoralves/OpenPLC_v3","tags":["product"]},{"url":"https://www.vulncheck.com/advisories/openplc-v3-heap-based-buffer-overflow-in-modbus-master-getdata","tags":["third-party-advisory"]}],"priority":{"score":16.4,"factors":[{"name":"EPSS percentile","points":10.22},{"name":"CVSS severity","points":6.16}]},"vendorSlug":"openplcproject","affectedVersions":[{"vendor":"openplcproject","product":"OpenPLC_v3","versions":["<= b470206"]}],"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2026-07-20T17:02:00.553936Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-45380","exploited":false,"provenance":"source"}}