{"id":"CVE-2026-118458","published":"2026-11-09T11:46:22Z","modified":"2026-11-12T16:03:42Z","title":"AIS shared test login provider contains fixed administrative credentials","vendor":"CompuGroup Medical","product":"Phronesis","tier":"tail","description":{"text":"The shared AIS login routing selects a production-shipped test DAO and plaintext comparison for the H and V application codes, accepting fixed administrator accounts.","provenance":"source","from":"CVE.org"},"cvss":{"score":8.1,"severity":"HIGH","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:U","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00249,"percentile":0.1653,"provenance":"source"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"}],"references":[{"url":"https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical","tags":[]},{"url":"https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html","tags":[]}],"priority":{"score":9.0,"factors":[{"name":"EPSS percentile","points":3.31},{"name":"CVSS severity","points":5.67}]},"vendorSlug":"compugroup-medical","affectedVersions":[{"vendor":"CompuGroup Medical","product":"Phronesis","versions":["<= 5.1.15.1.1"]},{"vendor":"CompuGroup Medical","product":"Venere","versions":["<= 5.1.15.1.1"]}],"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"total","timestamp":"2026-11-12T16:03:22.542759Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-120020","exploited":false,"provenance":"source"}}