{"id":"CVE-2026-12562","published":"2026-07-30T21:29:35Z","modified":"2026-07-31T15:39:49Z","title":"Toptech Systems RCU II+ and Multiload II+ Missing Authentication for Critical Function","vendor":"Toptech Systems","product":"RCU II+","tier":"tail","description":{"text":"The RCU II+ and Multiload II+ are vulnerable to an unauthenticated \nservice that exposes a debug interface granting full root-level access \nto the embedded system. This vulnerability stems from a \nnetwork-accessible port running a Target Communications Framework (TCF) \nservice that does not require any authentication, allowing an attacker \nto directly interact with the Linux environment that powers the device. \nOnce connected, an attacker can freely view and modify the filesystem, \nmanipulate running processes, and control network interfaces, enabling \ndeep alteration of system behavior.","provenance":"source","from":"CVE.org"},"cvss":{"score":8.8,"severity":"HIGH","version":"3.1","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00458,"percentile":0.4063,"provenance":"source"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"references":[{"url":"https://s3.amazonaws.com/docs.toptech.com/nonpublic/rcuiip_mliip_vrt.zip","tags":[]},{"url":"https://s3.amazonaws.com/docs.toptech.com/nonpublic/rcuiip_mliip_vrt.gz","tags":[]},{"url":"https://s3.amazonaws.com/docs.toptech.com/index.html#downloads/Firmware/RCUII+_MLII+_SMPII+/","tags":[]},{"url":"https://s3.amazonaws.com/docs.toptech.com/nonpublic/2025%2012%2001%20RCU%20IIPlus%20MultiLoad%20IIPlus%20Vulnerability%20Notice.pdf","tags":[]},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-211-03","tags":[]},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-211-03.json","tags":[]}],"priority":{"score":14.3,"factors":[{"name":"EPSS percentile","points":8.13},{"name":"CVSS severity","points":6.16}]},"vendorSlug":"toptech-systems","affectedVersions":[{"vendor":"Toptech Systems","product":"RCU II+","versions":["< 2025-11-24"]},{"vendor":"Toptech Systems","product":"Multiload II+","versions":["< 2025-11-24"]}],"solutions":{"items":["Toptech Systems provides two methods for remediating affected RCU II+ and Multiload II+ units: First, move the device to a closed or segmented network without untrusted access. Run one of the RCU II+/Multiload II+ Vulnerability Removal Tools (VRT) available at https://s3.amazonaws.com/docs.toptech.com/nonpublic/rcuiip_mliip_vrt.zip , https://s3.amazonaws.com/docs.toptech.com/nonpublic/rcuiip_mliip_vrt.gz. * This option does not require breaking Weights and Measures seals and has the least operational impact. Install the latest firmware from https://s3.amazonaws.com/docs.toptech.com/index.html#downloads/Firmware/RCUII+_MLII+_SMPII+/ . * This method requires stopping the bay and breaking the W&M seal. Be sure to back up the current ML configuration before performing the firmware update. For questions, contact Toptech Systems Support at security@toptech.com. Additional details are available in Toptech System's firmware vulnerability notice: https://s3.amazonaws.com/docs.toptech.com/nonpublic/2025%2012%2001%20RCU%20IIPlus%20MultiLoad%20IIPlus%20Vulnerability%20Notice.pdf ."],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2026-07-31T15:39:39.902412Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-51329","exploited":false,"provenance":"source"}}