{"id":"CVE-2026-14868","published":"2026-07-07T09:26:55Z","modified":"2026-07-07T12:07:31Z","title":"Weak encryption mechanism for User directory","vendor":"arcinfo","product":"PcVue","tier":"tail","description":{"text":"The encryption algorithm used to protect the configuration of user accounts, stored in the built-in user directory of PcVue projects, all versions prior to 17.0.0, is not strong enough for the level of protection required. A local attacker could alter the existing configuration and ultimately gain privileged access to the PcVue application.","provenance":"source","from":"CVE.org"},"cvss":{"score":8.4,"severity":"HIGH","version":"4.0","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/AU:Y/R:U/RE:M/U:Amber","provenance":"source","from":"CVE.org CNA"},"epss":{"score":0.00064,"percentile":0.00013,"provenance":"source"},"cwes":[{"id":"CWE-326","name":"Inadequate Encryption Strength"}],"references":[{"url":"https://www.pcvue.com/security/#SB2026-5","tags":["vendor-advisory"]}],"priority":{"score":5.9,"factors":[{"name":"CVSS severity","points":5.88}]},"vendorSlug":"arcinfo","affectedVersions":[{"vendor":"arcinfo","product":"PcVue","versions":["< 17.0.0"]}],"solutions":{"items":["Harden the configuration Who should apply this recommendation: All users To reduce the risk of exploitation, ARC Informatique strongly recommends implementing the following defensive measures: * Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from insecure networks. * Locate control system networks and remote devices behind firewalls and isolate them from business networks. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. Additional deployment guidance and recommended practices are available in the product documentation ( Hardening Guide https://www.pcvue.com/ProductHelp/PcVue/en/Content/Deployment/hardening-guide/overview.php ). Update PcVue Who should apply this recommendation: All users using the affected component Apply the corrective update by installing PcVue Initial Release 17.0.0 or later In a patched release, it will no longer be possible to load User directory from earlier versions. Existing projects…"],"from":"CVE.org CNA","provenance":"source"},"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total","timestamp":"2026-07-07T12:07:11.716678Z","from":"CISA ADP","provenance":"source"},"euvd":{"id":"EUVD-2026-42032","exploited":false,"provenance":"source"}}